Service Quality
and Customer Satisfaction Are at the Top of Our Priority List

Gas Detector Sales - Eaubonne

Portable Gas Detectors

Portable gas detectors are devices that are capable of estimating the concentration of one or more gases present in the atmosphere. They are stand-alone devices and should be light and easy to carry so that they can be worn by operators or held in one hand. Combined with a vibrator, an audible and visual warning, they respond immediately if the gas concentration level exceeds the alarm setpoint. They measure the risk of exposure and toxicity, as well as a lack or excessive amount of oxygen.

We have a comprehensive range of explosimeters, oxygen meters and portable gas detectors (CO, H₂S, O₂, NO₂, SO₂, NH₃, Cl₂, ClO₂, PH₃, HCN, Cl₂, ClO₂, O₃ and more). It can sometimes be tricky to find the right device for your specific needs.

All our portable gas detectors (disposable detectors, single-gas or multi-gas detectors) comply with the highest industry standards. Discover our most popular portable gas detectors on this page.

EZ-Sense gas detectors are designed to efficiently detect flammable gases, such as natural gas, butane, and propane. They are also incredibly easy to use.

Portable Gas Installation Ivry-sur-Seine 

T40 +

ATEX portable single-gas detector (CO or H2S)

ATEX T40 portable gas detector (CO or H2S): Large LCD screen for continuous display and the configuration of alarm thresholds, highly economical device backed by a 2-year warranty

Portable Gas Installation Ivry-sur-Seine 

GasBadge Plus +

Disposable ATEX toxic gas detector (O2 – CO – H2S – NO2 or SO2)

Disposable ATEX toxic gas detector with a 2-year lifespan: O2, CO, H2S, NO2 ou SO2. 
Continuous display of gas concentration and the battery charge.

Portable Gas Installation Ivry-sur-Seine 

RD99 +

Refrigerant Gas Leak Detector

RD99 detects all existing refrigerant gases, including CFCs (R11, R12, R13), HCFC (R22, R500, R502), HCF (R134a, R123, R125, R23), as well as the new ones (R404A R407C R410A).

Portable Gas Installation Ivry-sur-Seine 

GasBadge Pro +

Cl2, ClO2, CO, H2, H2S, HCN, NH3, NO2, O2, PH3, SO2 gas detector

Portable toxic gas detector featuring interchangeable sensors: Cl2 – ClO2 – CO – H2- H2S – HCN – NH3 – NO2 – O2- PH3 – SO2 with event logging and history.

Portable Gas Installation Ivry-sur-Seine 

Ventis MX4 +

ATEX 4-gas detector (EXPLO 0-100% LEL, O2, CO, H2S, NO2, SO2)

Detects 1 to 4 gases with a wide choice of sensors: EXPLO 0-100% LEL, O2, CO, H2S, NO2, SO2 – Optional integrated pump for confined spaces.

Sensors :

  • Flammable gases/methane : Catalytic diffusion
  • O2, CO, H2S, NO2, SO2 : Electrochemical
  • Range of gases detected :
  • Combustible gases : 0-100% LEL in 1% increments
  • Methane (CH4 ): 0-5% of vol. in 0.01% increments
  • Oxygen (O2) : 0-30% of vol. in 0.1% increments
  • Carbon Monoxide (CO) : 0-1,000 ppm in 1 ppm increments
  • Hydrogen Sulfide (H2S) : 0-500 ppm in 0.1 ppm increments
  • Nitrogen Dioxide (NO2) : 0-150 ppm in 0.1 ppm increments
  • Sulfur Dioxide (SO2) : 0-150 ppm in 0.1 ppm increments

Case Material: Polycarbonate with protective rubber overmold

Alarms: Ultra-bright LEDs, loud audible alarm (95 dB at 30 cm) and vibrating alarm

Power source /Run time :

  • Rechargeable Lithium-ion battery: Usually 12 hours at 20°C
  • Rechargeable extended-range Lithium-ion battery: Usually 20 hours at 20°C – Ventis diffusion
  • Usually 12 hours at 20°C - Ventis with pump
  • Replaceable AAA alkaline battery pack    
  • Usually 8 hours at 20°C- Ventis
  • Usually 4 hours at 20°C - Ventis with pump
  • Gas Detection Equipment Specialist Ivry-sur-Seine
Portable Gas Installation Ivry-sur-Seine 

Dimensions :

  • Ventis Lithium-ion: 103 mm x 58 mm x 30 mm
  • Ventis with pump: 172 mm x 67 mm x 66 mm

Weight :

  • Ventis Lithium-ion: 182 g
  • Ventis with pump: 380 g
  • Operating temperature and humidity range:
  • 20 °C- 50 °C –  15 to 95 % non-condensing (continuous)
  • Protection index: IP66 – IP67

Certifications :

UL: Class I, Division 1, Groups A B C D, T4
Class II, Groups F G (Dust)

AEx d ia IIC T4

ATEX: Ex d ia I Mb / Ex d ia IIC T4 Gb 
Equipment group and category I M2 and II 2G ECEx

Ex d ia IIC T4 Gb

CSA: Class I, Division 1, Groups A B C D, T4 C22.2 No. 152 Ex d ia IIC T4

MX4 +

ATEX 4-gas detector  (EXPLO 0-100% LEL, O2, CO, H2S, NO2, SO2)

Portable Gas Installation Ivry-sur-Seine 

MX6 +

Portable gas detector for measuring Volatile Organic Compounds (VOC) by photo-ionisation (PID)

ATEX 5-gas detector (LEL, O2, TOXIC, VOC)
Atmospheric VOC measurement and analysis

TECHNICAL FEATURES

  • VOC gas detector (Volatile Organic Compounds), PID sensor and the possibility of adding other sensors (up to 5 measuring methods):
  • Sampling pump as standard
  • Display/Screen: STN full-colour graphic LCD
  • Case material: Lexan/ABS/Stainless Steel w/protective rubber overmold
  • Dimensions: 135 mm x 77 mm x 43 mm without pump
  • Power source/ Run times:
  • Rechargeable Lithium-ion (Li-ion) battery : 24 hours
  • Rechargeable, extended-range Lithium-ion (Li-ion) battery: 36 hours
  • Replaceable AA alkaline battery pack: 10.5 hours

Certifications :

  • IECEx/ATEX: EEx ia d IIC T4 Group and equipment category: II 2G
  • UL: Class I, Groups A,B,C,D T4 ; AEx ia d IIC T4
  • CSA: Class I, Groups A,B,C,D T4
Portable Gas Installation Ivry-sur-Seine 

VOCs detected :

Acetaldehyde, Ethyl Acetate, Butyl Acetate, Acetone, Acetonitrile, Acetylene, Acrylonitrile, Acrolein, Benzene, Butadiene, Butane, Butanol, Butene, Chloroform, Chlorophenol, Methyl Chloride, Vinyl chloride, Chlorobenzene, CFCs (R11, R12, R13, R113, R114, R115), Dichlorobenzene, Dichloromethane, Dichloroethane, Dichloropropane, Dichloroethylene, Dibromomethane, Dibromoethane, Diethyl ketone, Ethane, Ethanol, Ethylbenzene, Heptane, Ethylene (ethene), Formaldehyde, Hexane, Hexene, Isoprene 1&2, Methanol, Naphthalene, Octane, Ethylene Oxide, Perchloroethylene, Pentane, Pentene, Phenol, Propane, Propanol, Propylene, Propyne, Styrene, Trichlorobenzene, Trichloroethylenes, Trichloroethanes, Trichloroethene, Tetrachloroethylene, Tetrachloroethane, Tetrachloromethane, Toluene, Trimethylbenzenes, Xylene

BM25 – MULTI-GAS AREA MONITOR +

It is designed to protect intervention or maintenance teams in areas of high gas-leak risks during short-term development or maintenance work.

BM25 offers a whole range of possible combinations with 32 interchangeable sensors. It can, therefore, be used in several industries, including petrochemistry, chemistry, refinery, pharmaceutics, work in confined spaces or water treatment plants...

The beacon is equipped with a 360° ultrabright flashlight and a 103dB audible alarm at one metre. STEL and TWA values are also available, along with a data logging capacity of 4 months (for 5-gas configuration). The batteries provide up to 170 hours of continuous runtime (depending on the configuration) and are fully recharged within only 4.5 hours. Moreover, the safe trickle charger allows long-term monitoring in classified zones.

The beacon may also be used in a network, allowing alarm transfer from one device to another to maintain a security perimeter.

TECHNICAL FEATURES

Deployable multi-gas detection system: natural diffusion or pumping version :

Sensors: Interchangeable pre-calibrated smart block without adjustment. Automatic sensor and parameter recognition (alarms, wear rate...).
Main gases detected: EXPLO – AsH3 – CL2 CO – CO2 – COCl2 – ETO – F2 – H2 – H2S HCL – HCN – HF – NO – NO2 – NH3 – O2 – O3 -PH3 – SiH4 – SO2 & VOC (Volatile Organic Compounds)
Display : Large backlit LCD display. FLIP FLAP function (display reversal)

Self-zero: upon start-up or on demand
Functional check:

  • Self-check upon commissioning
  • No sensor stabilisation time

Gas alarms :

On display, clear message per channel
Audiovisual signals depending on the alarm type
Alarm acknowledgement according to safety rules

Portable Gas Installation Ivry-sur-Seine 

Alarm levels :

  • 2 instantaneous thresholds per channel
  • ELV/OEL in toxic gas (alarm on sliding average over 15 minutes and 8 hours)
  • High and low alarm thresholds for oxygen (2 optional low thresholds)

Indicator light: 20 ultra-bright LEDs visible in all directions and protected by metal hoops

Two-way sounder: 103 db at 1m

Programmable inputs/outputs :

  • 2 inputs: 1 logic input for remote acknowledgement + 1 logic “knuckle” or “alarm report” or “interconnection” input
  • 2 logic relay output: 1 fault relay output + 1 gas alarm output
  • 1 specific input/output: 4-20mA, RS485…

Protection: IP 66 certified
Weight: approx. 6.8 kg
Dimensions: L 180 x H 467 x D195

Certifications :

  • II 1GD EEx ia IIC T4
  • II 2 GD EEx ia d IIC T4 (with CO2 sensor)

Power source: NiMH battery pack
Power supply in zone 0,1,2 possible through trickle charge
Charger: integrated and smart, powered by 12/30VDC or 110VAC,220VAC
Charging time: 4.5 hours
Run time: Example for EXPLO/O2/TOX1/TOX2 configuration: 100h

Get in touch with us